Skip to main content
Marine One crest MARINE ONE

Regulation explained

ISM Code §10

What it requires, why examiners ask it, the key figures and how it works on board.

Updated . Written from the regulation texts; paraphrased, with figures as the instruments give them.

What it requires

Section 10 of the ISM (International Safety Management) Code covers maintenance of the ship and its equipment. It is the basis of the planned maintenance system (PMS) in the safety management system (SMS). It has four parts.

  • Maintenance procedures (10.1). The company sets procedures so that the ship is kept in line with the relevant rules and regulations. It also keeps the ship in line with any extra requirements the company sets for itself.
  • What the procedures must deliver (10.2). The company ensures four things:
    1. inspections are held at appropriate intervals;
    2. any non-conformity is reported, with its possible cause if that is known;
    3. appropriate corrective action is taken;
    4. records of these activities are kept.
  • Critical equipment (10.3). The company identifies equipment and technical systems whose sudden failure in operation could lead to a hazardous situation. The SMS must give specific measures to make them more reliable. These include regular testing of stand-by arrangements, and of equipment or systems that are not in continuous use.
  • One routine (10.4). The inspections of 10.2 and the reliability measures of 10.3 are built into the ship's normal operational maintenance routine. They are not a separate programme.

The Code is worded with "should". It is still mandatory. SOLAS (Safety of Life at Sea) chapter IX, regulation 3 requires the company and the ship to comply with the ISM Code and treats its requirements as mandatory.

Key terms

  • A non-conformity is a situation seen on objective evidence where a specified requirement is not met (section 1.1.9).
  • A major non-conformity is a deviation that seriously threatens personnel, the ship or the environment and needs immediate corrective action. It also covers a lack of effective and systematic implementation of a Code requirement (section 1.1.10).

Why it is asked

Maintenance is the core of an engineer's job. Section 10 is where the ISM Code meets the engine room. Examiners use it to test whether a candidate can link a breakdown at sea to the SMS: report, cause, correction and record.

Typical questions are:

  • How do you carry out maintenance under the SMS?
  • The oily water separator fails just before entering port. No spare is on board and the downtime is a month. What do you do as Chief Engineer?
  • You find a surface crack on a propeller blade in dry dock. What steps do you take, and what do you tell the company?
  • Only the Second and Third Engineers are on board and the Third Engineer refuses to come to the engine room. What do you do?
  • How can a Chief Engineer achieve a successful voyage with trouble-free machinery?

The examiner looks for the four elements of 10.2, the idea of critical equipment, the testing of stand-by equipment, and the link to the PMS (10.4). In scenario questions they want to see the non-conformity reported with its cause, and corrective action recorded.

Regulations and key figures

Instrument Locus What it requires
ISM Code Section 10.1 Company procedures to keep the ship in conformity with rules, regulations and any additional company requirements
ISM Code Section 10.2.1 to 10.2.4 Inspections at appropriate intervals; non-conformities reported with possible cause if known; corrective action; records kept
ISM Code Section 10.3 Company identifies equipment and systems whose sudden failure may cause hazardous situations; specific reliability measures, including regular testing of stand-by and non-continuous equipment
ISM Code Section 10.4 The 10.2 inspections and 10.3 measures integrated in the ship's operational maintenance routine
ISM Code Section 1.1.9 and 1.1.10 Definitions of non-conformity and major non-conformity
ISM Code Section 1.2.3 SMS ensures compliance with mandatory rules and takes into account codes and standards of IMO (International Maritime Organization), Administrations, classification societies and industry
ISM Code Section 5.1.5 Master periodically reviews the SMS and reports its deficiencies to shore management
ISM Code Section 8.1 to 8.3 Company identifies potential emergencies, sets response procedures and drills, and can respond at any time
ISM Code Section 9.1 and 9.2 Non-conformities, accidents and hazardous situations reported to the company, investigated and analysed; corrective action includes measures to prevent recurrence
ISM Code Section 12.1 Internal safety audits at intervals not exceeding twelve months, extendable by not more than three months in exceptional circumstances
SOLAS Chapter IX, regulation 3.1 Company and ship comply with the ISM Code; its requirements treated as mandatory
Merchant Shipping Act 2025 Section 115(a) "Company" means the owner or the person who has taken over the ship's operation and the duties of the ISM Code
Merchant Shipping Act 2025 Section 116(1)(a) Every vessel complies with the Safety Convention, as applicable
Merchant Shipping Act 2025 Section 147 Every vessel, company or port is surveyed, audited and certified for compliance with the applicable conventions

On board

The company writes the maintenance procedures and names the critical equipment. The ship's engineers carry out the work, report what they find and keep the records.

Chief Engineer (Class 1)

  • Runs the engine department's PMS and makes sure jobs are done when due.
  • Checks that the critical equipment list covers the machinery whose sudden failure would be hazardous. Proposes changes to the company where it does not.
  • Reports non-conformities and breakdowns to the company with the possible cause, and agrees corrective action.
  • When critical equipment fails and cannot be repaired at once, informs the Master and the company, and puts temporary measures in place. Examples are a failed oily water separator or steering gear defect.
  • Reviews records for completeness before audits and surveys.

Second Engineer (Class 2)

  • Plans and carries out the day-to-day maintenance in the PMS.
  • Records each job, the parts used and the condition found.
  • Arranges regular testing of stand-by pumps, emergency generator and other equipment not in continuous use.
  • Raises a non-conformity report when a defect is found, giving the likely cause.
  • Manages spare parts for critical equipment.

Engineer Officer of the Watch (Class 4)

  • Carries out the routine inspections and tests assigned in the PMS and records them.
  • Changes over and tests stand-by machinery as scheduled.
  • Reports defects and abnormal readings at once, through the SMS procedure.

Electro-Technical Officer (ETO)

  • Maintains and tests electrical, automation, alarm and safety systems under the PMS.
  • Tests stand-by electrical arrangements, such as emergency power and change-over systems, at the set intervals.
  • Records findings and reports defects with their possible cause.

India. The Merchant Shipping Act 2025 requires every vessel to comply with the Safety Convention, that is SOLAS, whose chapter IX makes the ISM Code mandatory (section 116). For that part of the Act, "company" carries the ISM Code meaning (section 115). Every vessel and company is surveyed, audited and certified for compliance (section 147).

Related topics

  • Planned maintenance scheme (PMS)
  • Condition monitoring and condition-based maintenance
  • ISM Code, section 9: reports and analysis of non-conformities
  • ISM Code, section 8: emergency preparedness
  • ISM Code, section 12: company verification, review and evaluation
  • Oily bilge water separator (OWS)
  • Voyage repairs and maintenance

Traps and follow-ups

  • Leaving out the cause. A non-conformity is reported with its possible cause, if known. Many answers stop at "report the defect".
  • Treating critical equipment as a separate system. Section 10.4 requires the inspections and critical-equipment measures to be built into the normal maintenance routine.
  • Forgetting stand-by and idle equipment. Section 10.3 names regular testing of stand-by arrangements and equipment not in continuous use. The emergency generator and stand-by pumps are the usual examples.
  • Only rules and regulations. Section 10.1 also covers extra requirements the company sets for itself.
  • "Should" means optional. It does not. SOLAS chapter IX, regulation 3 makes the Code mandatory.
  • No record, no evidence. An auditor or surveyor judges maintenance by its records. A job done but not recorded counts as not done.

Likely follow-ups:

  • Which engine-room equipment would you list as critical, and why?
  • What is the difference between a non-conformity and a major non-conformity?
  • How is a non-conformity closed out?
  • What is the role of the Designated Person Ashore when critical equipment fails?
  • How does condition monitoring fit into the PMS?

Short forms on this page: CLC: Civil Liability Convention.