What it requires
Regulation 14 of MARPOL (the convention on pollution from ships) Annex VI controls sulphur oxides (SOx) and particulate matter by limiting the sulphur in fuel oil.
Worldwide limit (14.1)
- Fuel oil used on board, or carried for use on board, must not exceed 0.50% m/m sulphur.
- The words "carried for use" matter. A ship without an approved equivalent may not even carry non-compliant fuel for its own use.
Monitoring (14.2)
- The worldwide average sulphur content of residual fuel supplied to ships is monitored under IMO (International Maritime Organization) guidelines (MEPC.326(75)).
Emission control areas (14.3 and 14.4)
- Inside an emission control area (ECA), fuel oil used must not exceed 0.10% m/m sulphur.
- An ECA can include port areas. The ECAs listed in regulation 14.3 are:
- the Baltic Sea area;
- the North Sea area;
- the North American ECA;
- the United States Caribbean Sea ECA;
- the Mediterranean Sea ECA;
- the Canadian Arctic ECA;
- the Norwegian Sea.
Documentation (14.5)
- The supplier documents the sulphur content on the bunker delivery note, as regulation 18 requires.
Fuel change-over (14.6)
- A ship that uses separate fuels to meet the ECA limit must carry a written change-over procedure.
- The procedure must allow enough time to flush the fuel oil service system of all fuel above 0.10% before the ship enters the ECA.
- The ship records, in the log-book or electronic record book prescribed by the Administration:
- the volume of low-sulphur fuel in each tank;
- the date, time and position when the change-over is completed before entry;
- the date, time and position when the change-over is started after exit.
New ECAs (14.7)
- For the first twelve months after an amendment designating a new ECA enters into force, ships in that ECA are exempt from the 0.10% limit, the change-over procedure and record, and the related supplier documentation.
Sampling (14.8 to 14.13)
- A competent authority may analyse the in-use sample or an onboard sample. The analysis follows the verification procedure in appendix VI of the Annex.
- The sample is sealed by the authority's representative, with a unique identification, in the presence of the ship's representative. The ship may keep a duplicate.
- Ships subject to regulations 5 and 6 (survey and IAPP certification) must have sampling points fitted or designated for the fuel in use.
- A ship constructed before 1 April 2022 must have these sampling points no later than the first renewal survey on or after 1 April 2023.
- Sampling points are not required for a service system using low-flashpoint fuel or gas fuel.
- The authority must take samples as quickly as possible without unduly delaying the ship.
Equivalents (regulation 4)
- The Administration may accept a fitting, appliance, alternative fuel or compliance method instead of compliant fuel, if it is at least as effective in reducing emissions. Regulation 4 names regulation 14 among the standards this applies to.
- The guidelines it points to are the 2015 Guidelines for exhaust gas cleaning systems (MEPC.259(68)).
Why it is asked
The sulphur limit touches the Chief Engineer's work at every bunkering and every ECA passage. Examiners use it in several ways:
- Bunker quality and disputes. A correct bunker specification must at least meet the statutory sulphur limit. The MARPOL sample and the bunker delivery note decide a dispute.
- Port State control. Questions on the 0.50% cap and the carriage ban ask which deficiencies lead to detention and how to prevent them.
- Voyage planning. A long voyage plan must allow for compliant fuel, ECA entry and change-over time.
- Emission reduction. Questions on IMO measures to reduce emissions expect the SOx limits and the use of approved equivalents.
The examiner wants the two figures (0.50% and 0.10% m/m), the carriage ban, the ECA list, the change-over record, and the sampling and documentation chain.
Regulations and key figures
| Instrument | Locus | What it requires |
|---|---|---|
| MARPOL Annex VI | regulation 14.1 | Sulphur in fuel oil used or carried for use on board not to exceed 0.50% m/m |
| MARPOL Annex VI | regulation 14.2 | Worldwide average sulphur of residual fuel supplied is monitored (MEPC.326(75)) |
| MARPOL Annex VI | regulation 14.3 | Seven ECAs: Baltic Sea, North Sea, North American, United States Caribbean Sea, Mediterranean Sea, Canadian Arctic, Norwegian Sea |
| MARPOL Annex VI | regulation 14.4 | Inside an ECA, sulphur in fuel oil used not to exceed 0.10% m/m |
| MARPOL Annex VI | regulation 14.5 | Sulphur content documented by the supplier under regulation 18 |
| MARPOL Annex VI | regulation 14.6 | Written change-over procedure; tank volumes, date, time and position recorded at change-over before entry and after exit |
| MARPOL Annex VI | regulation 14.7 | Twelve-month exemption after a new ECA designation enters into force |
| MARPOL Annex VI | regulation 14.8, 14.9 | In-use and onboard samples analysed under appendix VI; sealed in the presence of the ship's representative; ship may keep a duplicate |
| MARPOL Annex VI | regulation 14.10 to 14.13 | Sampling points for fuel in use; ships built before 1 April 2022 fitted by the first renewal survey on or after 1 April 2023; not for low-flashpoint or gas fuel |
| MARPOL Annex VI | regulation 4.1 | Approved equivalents at least as effective in emission reduction may replace compliant fuel (exhaust gas cleaning guidelines MEPC.259(68)) |
| MARPOL Annex VI | regulation 18.2 | If compliant fuel is not available, the ship shows its attempts to buy it and notifies its Administration and the port of destination |
| MARPOL Annex VI | regulation 18.5, 18.6 | Bunker delivery note for each delivery, kept on board for three years |
| MARPOL Annex VI | regulation 18.8.1 | Representative sample sealed and signed by the supplier's representative and the master or officer in charge of bunkering; kept until the fuel is substantially consumed and not less than 12 months |
| Merchant Shipping Act 2025 | section 134(1)(a) | Every vessel complies with the MARPOL Convention, as applicable |
| Merchant Shipping Act 2025 | section 135 | No vessel proceeds to sea without valid pollution prevention certificates; a vessel may be detained if its certificate or condition is not valid |
On board
Chief Engineer (Class 1)
- Plans bunkers so that the ship always has fuel at or below 0.50% m/m for use, and 0.10% m/m fuel for any ECA on the route.
- Makes sure no non-compliant fuel is carried for use, unless the ship has an approved equivalent.
- Keeps the written change-over procedure current and makes sure the flushing time is enough for the actual service system.
- Checks that change-over records (tank volumes, date, time, position) are complete before entry to and after exit from an ECA.
- Checks the bunker delivery note against the order, including the stated sulphur content.
- If compliant fuel cannot be bought, keeps a record of the attempts made and makes sure the Administration and the port of destination are notified (regulation 18.2).
- Where an exhaust gas cleaning system is the approved equivalent, makes sure it is operating whenever non-compliant fuel is used.
Second Engineer (Class 2)
- Usually acts as the officer in charge of bunkering in the engine room.
- Witnesses the drawing of the representative sample. Signs and seals it with the supplier's representative.
- Keeps the sample under the ship's control for at least 12 months and until the fuel is substantially consumed.
- Plans tank segregation so that high- and low-sulphur fuels are not mixed.
- Carries out or supervises the change-over and flushing of the service system.
Engineer Officer of the Watch (Class 4)
- Carries out the change-over on the watch when instructed, following the written procedure.
- Records tank volumes, date, time and position in the prescribed log at completion before ECA entry, and at the start after exit.
- Knows where the in-use sampling point is, so that an inspector's sample can be taken quickly.
Electro-Technical Officer (ETO)
- Maintains the monitoring and control instruments of an exhaust gas cleaning system, where fitted as an equivalent.
- Keeps the data-recording equipment used for compliance evidence working.
India. The Merchant Shipping Act 2025 requires every vessel to comply with the MARPOL Convention (section 134). No vessel may proceed to sea without valid pollution prevention certificates. A vessel may be detained if it has no valid certificate on board or its condition does not match the certificate (section 135).
Related topics
- MARPOL Annex VI regulation 18: fuel oil availability and quality, bunker delivery note and MARPOL sample
- MARPOL Annex VI regulation 4: equivalents and exhaust gas cleaning systems
- MARPOL Annex VI regulations 5 and 6: surveys and the IAPP Certificate
- MARPOL Annex VI regulation 13: nitrogen oxides
- Fuel change-over procedure before ECA entry
- Bunkering procedure and bunker quality disputes
- Port State control and detainable deficiencies
Traps and follow-ups
Common mistakes
- Saying 0.50% applies only to fuel burned. It applies to fuel used or carried for use.
- Saying the 0.10% limit applies to fuel carried in an ECA. Regulation 14.4 applies it to fuel used while in the ECA.
- Listing only four ECAs. The current text of regulation 14.3 lists seven.
- Doing the change-over at the ECA boundary. The procedure must allow time to flush the system fully before entry.
- Forgetting the record. Volumes, date, time and position must be recorded at both entry and exit.
- Mixing up the two samples. The MARPOL sample is drawn at delivery under regulation 18.8.1. The in-use and onboard samples are taken by the authority under regulation 14.8.
Next questions an examiner asks
- What must the bunker delivery note contain, and how long is it kept?
- How is a representative sample drawn, who seals it, and how long is it kept?
- What do you do if compliant fuel is not available at the bunkering port?
- What is an equivalent under regulation 4, and how does an exhaust gas cleaning system meet regulation 14?
- What deficiencies linked to the sulphur limit can lead to detention, and how do you prevent them?
- Which ECAs are also controlled for nitrogen oxides under regulation 13?